Perioperative disturbances of microvascular blood flow and oxygenation in the intestinal tract have been hypothesized to play an important role in development of the multiple organ dysfunction syndrome. Herein, increased intra-abdominal pressure (IAP) has been identified as a key factor in the initiation of the pathophysiologic cascade. The authors hypothesized that increasing the IAP by intraperitoneal insufflation of carbon dioxide attenuates microvascular oxygen saturation in gastric mucosa. They tested this hypothesis in a prospective, observational study in 16 patients scheduled to undergo elective diagnostic laparoscopy.
The authors continuously assessed microvascular oxygen saturation in gastric mucosa by reflectance spectrophotometry. Simultaneously systemic oxygen saturation, heart rate, arterial blood pressure, and ventilation-derived variables were measured noninvasively. During general anesthesia and controlled mechanical ventilation, baseline values were obtained. Thereafter, the IAP was increased to 8 and 12 mmHg, respectively, followed by a control period after desufflation.
The increase in IAP from baseline to 8 mmHg decreased microvascular oxygen saturation in gastric mucosa from 69+/-7% (mean +/- SD) to 63+/-8% at 8 mmHg IAP (P <0.05), with a further significant reduction to 54+/-13% at 12 mmHg IAP (P <0.01). Microvascular oxygen saturation in gastric mucosa recovered rapidly to baseline level (66 +/- 10%) after release of increased IAP. In striking contrast to regional mucosal oxygen saturation, systemic oxygenation did not change with either of the interventions.
The results suggest that increasing intraabdominal pressure to moderate levels, commonly applied to induce a surgical pneumoperitoneum, decreases gastric mucosal oxygen saturation.
INTRAABDOMINAL hypertension is a clinical condition associated with high morbidity and mortality. With a cutoff at 12 mmHg, the intraabdominal pressure (IAP) has been shown to be an independent predictive factor for intensive care unit and hospital mortality with high specificity (91.6% and 81.7%, respectively) and accuracy (86.9% and 79.8%, respectively); the higher the IAP value, the poorer the survival. 1Within this concept, increased IAP has been identified as a major component in the development of the multiple organ dysfunction syndrome. 1,2In view of the hypothesized pivotal role of the gut in the pathogenesis of this syndrome, 3,i.e. , by disturbances of microvascular blood flow and mucosal barrier function, 4–7possible adverse effects of increased IAP on splanchnic circulation and oxygenation are of pertinent interest. Increases in IAP to 25 mmHg for 60 min have been implicated in the occurrence of decreased mesenteric blood flow and hence the loss of mucosal barrier function. 8
In experimental animals, increasing the IAP by different techniques, e.g. , insufflation of an intraabdominal balloon, intraperitoneal insufflation of carbon dioxide, helium, or air, has been shown to compromise splanchnic perfusion. 9–11Consequently, a decrease in tissue partial pressure of oxygen (Po2) in the ileum in response to increased IAP has been documented in a porcine model of abdominal hypertension. 10However, because of the lack of applicable methods in patients to directly assess tissue oxygenation, measurements of splanchnic mucosal oxygenation during increased IAP have been restricted to experimental settings. 10No data have been published on this issue in patients so far.
We hypothesized that the increase in IAP decreases microvascular oxygen saturation in gastric mucosa (μHbO2) pressure level dependently. To test this hypothesis, we studied the effect of different levels of IAP on μHbO2and the reversibility of these effects in anesthetized patients. In this setting, μHbO2was assessed directly in gastric mucosa by reflectance spectrophotometry. 12This method allows for continuous measurement of microvascular oxygen saturation in volunteers and patients. 13–15
Materials and Methods
Patients
The study protocol was approved by the local Institutional Review Board (Ethics Committee, Medical Faculty, Heinrich-Heine-University, Düsseldorf, Germany) and performed in compliance with the principles established in the Helsinki Declaration. Sixteen patients scheduled to undergo elective, diagnostic laparoscopy were included consecutively after a full explanation of the study and obtaining written informed consent. Exclusion criteria included withdrawal of consent, history of gastrointestinal illness, cardiopulmonary diseases, and diabetes mellitus. Patients had ovary cysts, myoma, endometriosis, or infertility. The average patient age was 31 ± 9 yr (mean ±SD). The patients’ mean size and body weight were 167 ± 7 cm and 64 ± 14 kg, respectively, resulting in an average body mass index of 22.9 ± 4.5 kg/m2. Nine patients had American Society of Anesthesiologists physical status class I, and three patients had class II.
Anesthesia and Ventilation
Food was withheld for 8 h before the measurements to ensure gastric depletion. Premedication consisted of 7.5 mg midazolam orally. Anesthesia was induced with thiopentone (3–5 mg/kg) and was maintained with sevoflurane (end-tidal concentration, 1.6–1.8 vol%) in 30% oxygen balanced in air. Analgesia was supplemented with alfentanil (10 μg/kg, followed by 10–30 μg · kg−1·h−1). Tracheal intubation was facilitated with rocuronium (0.6 mg/kg); neuromuscular block was maintained with 0.1-mg/kg increments. Mechanical ventilation (Cicero EM; Dräger, Lübeck, Germany; tidal volume, 9 ml/kg; inspiratory:expiratory cycle time, 1:1.7; positive end-expiratory pressure, 0 cmH2O) was set meticulously to maintain normocapnia (end-tidal partial pressure of carbon dioxide [ETco2], 36 ± 3 mmHg, verified by continuous capnography) by adjusting respiratory rate.
The patients were hydrated with lactated Ringer’s solution (10 ml · kg−1·h−1). During the study, the patients were lying in the supine position and were covered with warming blankets (Bair Hugger; Arizant Inc., Eden Prairie, MN) to preserve body temperature.
Measurements
Tissue Reflectance Spectrophotometry.
We applied reflectance spectrophotometry (Erlangen Microli-ghtguide Spectrophotometer, EMPHO II; Bodensee Gerätetechnik GmbH, Überlingen, Germany) to assess microvascular oxygen saturation of hemoglobin in gastric mucosa as previously reported in patients and volunteers. 14,15The EMPHO consists of four functional modules: a light source, a micro–light guide probe, a detection device, and a personal computer. The light from a xenon high-pressure arc lamp is transmitted by a highly flexible micro–light guide (250-μm diameter) to the tissue. The color of this light changes corresponding to the oxygen saturation of hemoglobin in tissue. The reflected light in the tissue is transferred back by a hexagon of six light guides (250-μm diameter) surrounding the illuminating light guide. All light guides are encased in a flexible rubber tube with an OD of approximately 2.0 mm. The backscattered light is passed through a rotating interference bandpass filter disk, where it is split into its spectral components. These spectra are fitted to known spectra, starting with the spectra of fully oxygenated and fully deoxygenated hemoglobin, in an iteration process with a resolution of 1 nm to provide absolute data of μHbO2(EMPHO II software, version 2.0; Bodensee Geräte Technik, Friedrichshafen, Germany). 12
The light guide probe was introduced via an orogastric tube (14 Charrière) inserted for 50 cm from the upper row of teeth into the stomach. The position of the tube in the stomach was identified by insufflating a small volume (approximately 20 ml) of ambient air into the tube during auscultation over the epigastrium 14,15and by the aspiration of gastric contents. 16During the study period, the stomach was drained via this tube to prevent gastric distension.
The measuring probe was introduced via the orogastric tube (length marker on the probe to assure that the tip of the probe was 1 cm beyond the distal opening of the orogastric tube after inserted up to the length marker). The precise contact of the measuring probe with the gastric mucosa was ascertained by continuous evaluation of the shape of the absorption curve on the monitor screen of the EMPHO as detailed previously. 14,15,17,18The scattering of μHbO2data points from the average value during steady state conditions was below ± 2% (fig. 1). Values given refer to the mean value over the last 2 min at the end of each intervention.
Intraabdominal Pressure.
Measurement of IAP was accomplished by the introduction of a Veress cannula (OD, 2.1 mm; Karl Storz GmbH & Co KG, Tuttlingen, Germany) into the abdominal cavity via a periumbilical incision. Medical carbon dioxide was insufflated intermittently at a flow of 1.5 l/min through this cannula until the IAP reached and maintained the target level (Thermoflator; Karl Storz GmbH & Co KG).
Systemic Hemodynamics and Oxygenation.
We assessed systemic hemodynamics, i.e. , heart rate (electrocardiographically triggered cardiotachometer) and arterial blood pressure, noninvasively (automatic oscillometer, Cardiocap II; Datex-Engstrom, Helsinki, Finland). We continuously measured systemic oxygen saturation by pulse oximetry (Cardiocap II).
Study Protocol
At least 20 min were allowed after induction of anesthesia and instrumentation to establish steady state conditions with respect to anesthesia, hemodynamics, ventilation, metabolism (constant inspiratory-to-expiratory gradient of oxygen concentration, ETco2), and systemic and regional oxygen saturation before collection of data was started. Thereafter, the IAP was increased to 8 and 12 mmHg, respectively, followed by release of increased IAP. Data were compared during steady state conditions at four time points: (1) baseline measurements, performed with the Veress cannula in situ with 0 mmHg superimposed IAP (baseline); (2) during an IAP of 8 mmHg; (3) during an IAP of 12 mmHg; and (4) after release of increased IAP (control). Each measurement period lasted 15 min, a time sufficient to achieve stable values of the assessed variables.
Statistical Analysis
Statistical calculations and analysis were performed using StatView (version 5.0; SAS Institute, Inc., Cary, NC) and JMP software (version 5.0.1a; SAS Institute, Inc.). Patient group size calculations were derived from a previous study in volunteers, 15according to which we calculated that at least 13 patients had to be studied to detect a 10% diminution in μHbO2with an agr;error of 0.05 and a power of 0.95 based on a SD of 9% within μHbO2measurements. We decided to consecutively include 16 patients in the study group.
The results obtained are given as mean ± SD. After confirming normal distribution of our data (Kolmogorov-Smirnov test), one-way analysis of variance for repeated measurements was used to analyze continuous variables measured over time. The following hypotheses were tested: Increases in IAP cause a pressure level–dependent reduction in μHbO2, and there is no significant difference in values of μHbO2during baseline and control measurements after release of increased IAP. In case of significance, Scheffépost hoc test was applied to identify significant differences. Statistical significance was assumed if the αerror was smaller than 5%.
Results
All patients fulfilled the study protocol, and none had to be excluded because of missing data. They experienced an uneventful course and recovery from anesthesia, and none of them developed clinically significant signs of gastrointestinal complications before hospital discharge. Because of dislocation, the probe for μHbO2measurements had to be repositioned in three patients. Reposition was not followed by different readings.
Gastric Mucosal Oxygen Saturation
Analysis of variance for repeated measurements showed significant effects of the level of IAP on μHbO2(P < 0.0001). Increasing IAP pressure level dependently attenuated μHbO2(fig. 2), resulting in a decrease from 69 ± 7% at baseline to 63 ± 8% (mean ± SD) at 8 mmHg IAP (P < 0.05). The decrease in μHbO2was even more pronounced with the increase in IAP from 8 to 12 mmHg, i.e., from 63 ± 8% to 54 ± 13% (P < 0.01). Release of increased IAP resulted in a rapid return in μHbO2almost to baseline, i.e., to 66 ± 10%
Systemic Oxygen Saturation
In striking contrast to regional oxygen saturation, the stepwise increase and subsequent release in IAP did not influence systemic oxygen saturation, which remained stable throughout all interventions (table 1).
Systemic Hemodynamics and Ventilation
The increase in IAP from baseline to 8 mmHg increased mean arterial pressure (MAP) by 14 mmHg (P <0.05), whereas the increase in IAP from 8 to 12 mmHg had no significant additional effect on MAP (table 1). Heart rate increased slightly with the increase in IAP and decreased with release of increased IAP, although these changes did not reach the level of significance (table 1).
End-tidal carbon dioxide remained stable during all interventions by increasing respiratory rate to adjust minute ventilation (table 2). Peak and mean airway pressure increased slightly in order with the increases in IAP to 8 and 12 mmHg, respectively (table 2). Both pressures returned to their respective baseline levels during the control period after desufflation, despite still-increased minute ventilation compared with baseline measurements. End-tidal concentrations of sevoflurane did not vary significantly during the anesthetic procedure (table 2).
Discussion
This is the first study in patients directly assessing microvascular oxygen saturation in gastric mucosa during increased intraabdominal pressure. The main finding is that the increase in IAP to moderate levels, i.e. , 12 mmHg or less, significantly decreased gastric mucosal oxygen saturation despite stable systemic oxygen saturation. These effects were rapidly and completely reversed by the release of increased IAP.
Critique of Methods
We applied reflectance spectrophotometry to continuously assess μHbO2. The validity of oxygen saturation measurements in intestinal mucosa using reflectance spectrophotometry has been demonstrated by Hasibeder et al. , 19comparing μHbO2data with simultaneously recorded microvascular Po2values provided by surfacePo2electrodes. Moreover, spectrophotometric measurements have been shown to be consistent with regional perfusion data in gastroduodenal mucosa assessed by the hydrogen gas clearance technique. 20Normal values of μHbO2in volunteers spontaneously breathing ambient air have been reported to be 59 ± 7%. 15
Oxygen saturation measurements applying reflectance spectrophotometry comprise arterial, capillary, and venous blood; although the exact proportions are unknown, capillary blood probably represents the major source of the reflected light from tissue. 21The EMPHO detects this light from a depth of less than 1 mm, i.e. , only from gastric mucosa. 21
Our technique to place the micro–light guide via an orogastric tube allowed identification of the location of the measuring probe in the stomach but did not provide information regarding the precise area of gastric mucosa being monitored. However, μHbO2values in humans do not show major variability between various mucosal observation sites in the stomach and in the upper small intestine. 13In addition, although the changes in μHbO2in gastric mucosa in our patients during increased IAP might not represent the absolute values of what is occurring in the entire splanchnic region, it can be speculated that the changes in μHbO2during increased IAP were mirrored by comparative concurrent alterations in other splanchnic organs. This view is supported by simultaneous laser Doppler flow measurements in patients undergoing laparoscopy with a carbon dioxide pneumoperitoneum showing decreases in mucosal blood flow in all intestinal organs up to 54%. 22
The supine position of the patients on the table was standardized and maintained throughout the entire observation period because positional changes could have affected systemic and regional circulation. 23During the study period, all patients received a standardized inhalation anesthesia regimen with sevoflurane, carefully adjusted to meet the anesthetic requirements. The variation in μHbO2with increasing IAP should not have been influenced by sevoflurane because end-tidal concentrations of this anesthetic did not differ significantly between the measurement phases (table 2).
We used the intermittent flow mode of the Thermoflator to induce and control the level of intraabdominal pressure. In this mode, the IAP is measured during the no-flow phases, i.e. , it cannot be confounded by flow dynamics.
End-tidal carbon dioxide was assessed by capnography. This method has been shown to adequately guide ventilation during laparoscopy in patients with a carbon dioxide pneumoperitoneum. 24We maintained ETco2stable throughout the entire study period, a regimen that compensates for the acid–base disturbances elicited by intraabdominal insufflation of carbon dioxide. 25
Furthermore, our results could have been influenced by the selection of carbon dioxide to increase IAP. In patients undergoing laparoscopic surgery, gastric mucosal partial pressure of carbon dioxide (Pco2) increased slightly from 39 mmHg at baseline to 44 mmHg during a carbon dioxide pneumoperitoneum at 12 mmHg IAP despite stable ETco2. 26We cannot supply data on mucosal Pco2in our patients. However, on a theoretical basis, an increase in mucosal Pco2in an extent of 5 mmHg could elicit a modest rightward shift of the respective oxyhemoglobin dissociation curve and hence a minor decrease in μHbO2of 1–2%.
In a porcine model with stable ETco2, the insufflation of air decreased mesenteric artery blood flow during the entire bandwidth of increased intraabdominal pressures, whereas the insufflation of carbon dioxide reduced the flow only at an IAP level greater than 12 mmHg. 11Thus, one might speculate that in our study, the attenuation of μHbO2would probably have been even more pronounced with the insufflation of air compared with the insufflation of carbon dioxide.
Interpretation of Results
The baseline values of μHbO2in our patients were within the physiologic range observed in healthy volunteers. 15Direct measurements of splanchnic mucosal oxygenation during increased IAP in patients have not yet been reported. However, similar to our results, indicating reduced regional despite unchanged systemic oxygen saturation during increased IAP, Bongard et al. 10reported in a porcine model a decrease in Po2in the ileum in response to an increase in IAP despite unaltered Po2in the subcutaneous tissue. Comparable to our data, an impairment of splanchnic perfusion–oxygenation corresponding to the level of IAP has been demonstrated in patients by gastric tonometry and the calculation of intramucosal pH. 27,28Furthermore, these studies reported a direct relation between abnormally low intramucosal pH and outcome. 27,28
Microvascular oxygen saturation reflects the balance of local oxygen influx to consumption. 13Therefore, the attenuation of μHbO2during increased IAP could be attributed to increased consumption, to decreased systemic or regional oxygen supply, or to a combination of both. Increased regional oxygen consumption cannot be excluded completely in our study, although there is no experimental evidence supporting the idea of enhanced mucosal oxygen consumption during increased IAP. However, even though MAP and heart rate were well maintained during abdominal hypertension in our patients, compromised systemic or regional oxygen supply with incremental levels of IAP might have contributed to the decrease in μHbO2Intraabdominal hypertension and its transmission to the thoracic cavity increases venous resistance and may thus decrease both inferior and superior vena cava flow, resulting in reduced preload and consequently decreased cardiac output. 29–32However, the cutoff point for the impairment of venous return at 15 mmHg IAP is well above the levels of IAP applied in our study; actually, IAP pressures of 10–15 mmHg have been reported to enhance venous return by the mobilization of blood from capacitance vessels in the abdomen. 33This may account for the slight increase in cardiac output demonstrated with moderate increases in IAP. 30,34
The increase in MAP in our study with increasing IAP probably reflects an increase in systemic vascular resistance as recently reported in patients during laparoscopic surgery. 35However, because the increases in MAP were counterbalanced in part by the simultaneous increase in IAP, the abdominal perfusion pressure 36remained fairly stable, e.g. , MAP increased only by 5 mmHg during the pressure step in IAP from 8 to 12 mmHg (table 1). In addition, in view of a considerably broad range of autoregulation of perfusion in the gut, 37it is unlikely that changes in MAP in a range as observed in our study can account for the alterations in μHbO2.
From a mechanistic point of view, the abdominal cavity can be viewed as a single compartment of limited space. 38Therefore, any increase in one of its components amplifies mesenteric vascular resistance and may thus decrease perfusion. 29This view is corroborated by the study of Caldwell et al. 9The authors showed in a canine model that the organ blood flow decreased significantly during increased IAP for all intraabdominal viscera except the renal cortex and the adrenal gland. Moreover, the changes in regional perfusion could not be predicted from systemic values, i.e. , they were more pronounced than could be derived from the alterations in systemic hemodynamics alone. Therefore, the authors suggested that systemic effects together with local control mechanisms might be responsible for the changes in organ blood flow. 9
Impairment of perfusion in splanchnic organs during increased IAP has been reported in other studies—however, usually at higher levels than those applied in our patients. 9,39,40These discrepancies might be explained by differences in the ventilatory regimen: ETco2or arterial pH were not kept stable in these studies. 9,39,40We hypothesize that the resultant hypercapnia might have increased organ perfusion and thus outweighed the depressant effect of moderately increased IAP. This view is supported by findings of Akca et al. 41showing that hypercapnia improves tissue oxygenation.
Microvascular oxygen saturation in gastric mucosa recovered to baseline values after release of increased IAP, although minute ventilation remained increased almost to the same extent as during the increase in IAP to 12 mmHg (approximately 40% compared with baseline;table 2). Therefore, we suggest that the decrease in μHbO2during increased IAP was mediated primarily by the increase in IAP, whereas the increases in minute ventilation after desufflation (control period) to maintain ETco2within the physiologic range did not affect μHbO2to a measurable extent. This view is supported by our finding of increased peak and mean airway pressures during the increase in IAP to 8 and 12 mmHg, respectively, whereas both pressures returned to their respective baseline levels after release of increased IAP (table 2).
Clinical Implications
The gut is exceptionally susceptible to hypoperfusion and hence impaired oxygen supply during trauma and stress, 42–44,e.g. , it is most sensitive to the increase in IAP. 45The gut shows evidence of end-organ damage during intraabdominal hypertension well before the appearance of any classic clinical signs, i.e. , renal, pulmonary, and cardiovascular symptoms. 45,46Therefore, early recognition of compromised oxygen availability due to increased IAP and on-time intervention are recommended. This highlights the need for diagnostic tools to reliably monitor splanchnic oxygenation in clinically susceptible patients. As shown in our study, reflectance spectrophotometry meticulously measured μHbO2during the various stages of increased IAP. Because none of our patients developed clinically significant signs of gastrointestinal complications in the postoperative period, it seems unlikely that a short-term increase in IAP within the pressure and time limits in our study is sufficient to cause significant harm in patients with American Society of Anesthesiologists physical status class I or II. However, whether this also applies to prolonged surgical procedures and especially to patients with compromised cardiorespiratory function has yet to be determined.
To conclude, we detected significant reductions in μHbO2at low levels of IAP despite unchanged systemic oxygen saturation. These findings suggest that levels of IAP applied on a routine basis during laparoscopic surgery might actually compromise splanchnic oxygenation.