Background

Epidural anesthesia is sometimes initiated during general anesthesia, yet few data exist concerning efficacy of epinephrine-containing test doses.

Methods

Thirty-six patients were randomized to receive either 0.5 MAC isoflurane, 1 MAC isoflurane, or 0.5 MAC each (1 MAC total) of isoflurane and nitrous oxide. Each subject received intravenous saline followed by three test doses containing 45 mg lidocaine with 7.5, 15, and 30 micrograms epinephrine in a randomized, double-blind fashion. Heart rate and systolic, diastolic, and mean blood pressures were measured for 5 min after injection. Positive hemodynamic criteria identifying intravascular injection were determined from peak increases in hemodynamics during administration of saline. Dose-effect relationships between epinephrine and peak increases in hemodynamics were assessed with linear regression. Minimum required doses of epinephrine to produce peak positive hemodynamic increases on average were determined from linear regression.

Results

Positive hemodynamic criteria were identified as increases in heart rate > or = 8 beats/min, systolic blood pressure > or = 13 mmHg, diastolic blood pressure > or = 7 mmHg, and mean blood pressure > or = 9 mmHg. Significant dose-effect relationships were observed for epinephrine and peak increases in hemodynamics (correlation coefficients ranged from 0.61-0.91). Minimum required doses of epinephrine ranged from 6 to 19 micrograms depending on hemodynamic measurement and anesthetic group.

Conclusions

Hemodynamic responses to intravascular injection of test doses vary with dose of epinephrine and depth and type of general anesthetic used. Thus, the 15 micrograms epinephrine contained in the standard test dose may not be sufficient during all anesthetic conditions.

EPIDURAL anesthesia and analgesia sometimes are initiated during general anesthesia. [1,2]Administration of a test dose containing local anesthetic and epinephrine is common practice [3,4]to identify subarachnoid injection and to prevent unintentional intravascular injection of large doses of local anesthetic, which may lead to cardiac dysrhythmias and arrest. [5]During general anesthesia, subjective symptoms of intravascular injection [6]cannot be reported, and thus, hemodynamic changes are the only markers for intravascular injection. Unfortunately, few data are available concerning efficacy of intravascular injection of epidural test doses during general anesthesia. Tanaka et al. questioned the reliability of the commonly used adult epidural test dose (45 mg lidocaine containing 15 micro gram epinephrine)[3,7]for detection of intravascular injection during general anesthesia with isoflurane (1 vol %) and nitrous oxide (67%). [8]However, hemodynamic criteria for detection of intravascular injection of epinephrine-containing epidural test doses in adults have been determined only for awake subjects. [3]Criteria derived from awake adult subjects may not be applicable during general anesthesia, [8]because many general anesthetics, such as isoflurane, produce dose-dependent cardiovascular depression. [9]Furthermore, hemodynamic responses to epinephrine may vary with depth and composition of general anesthesia. This study was undertaken to determine positive hemodynamic test dose criteria and hemodynamic responses to epidural test doses containing different doses of epinephrine during general anesthesia with 0.5 MAC isoflurane, 1 MAC isoflurane, or 1 MAC total isoflurane and nitrous oxide (0.5 MAC each).

After institutional review board approval and informed consent were obtained, 36 ASA physical status 1 or 2 patients scheduled to undergo general anesthesia for elective surgery were enrolled in this study. Exclusion criteria included age younger than 18 yr or older than 45 yr, history of diabetes mellitus or cardiovascular disease, use of medications affecting the cardiovascular system, daily consumption of alcohol in excess of two beverages per day, or current use of recreational drugs.

All patients were premedicated with 2 mg midazolam and 100 micro gram fentanyl and were randomized to receive 0.5 MAC isoflurane, 1 MAC isoflurane, or 1 MAC total isoflurane and nitrous oxide (0.5 MAC each). The randomization was stratified such that each group consisted of six men and six women. Before induction of anesthesia, heart rate from the electrocardiogram (averaged every eight heart beats) and noninvasive blood pressures (model 9030570, Spacelabs Medical, Redmond, WA) were measured. The blood pressure cuff was placed on the arm without an intravenous catheter. Anesthesia was induced with 4 mg *symbol* kg sup -1 thiopental and muscle relaxation achieved using 0.1 mg *symbol* kg sup -1 vecuronium. The trachea was intubated and ventilation controlled to maintain an end-tidal carbon dioxide tension between 30 and 35 mmHg. Patients' lungs were ventilated at 6–8 breaths/min, with a tidal volume of 10–15 ml *symbol* kg sup -1. Anesthesia was maintained with stable end-tidal concentrations of 0.5 MAC isoflurane (0.6 vol%), [10]1 MAC isoflurane (1.2 vol%), [10]or 0.5 MAC isoflurane with 0.5 MAC nitrous oxide (52%)[11]for 15 min. End-tidal gas concentrations were determined with an infrared end-tidal gas analyzer (Poet IQ model 602–6A, Criticare Systems, Milwaukee, WI). No other medications were administered. Body temperature was measured via an esophageal stethoscope (Mon-a-therm, Mallinckrodt, St. Louis, MO). Four test solutions were administrated to each subject. First saline (3 ml), then in a randomized, double-blind fashion, three test doses of 45 mg lidocaine (3 ml 1.5% lidocaine) containing 7.5 mg, 15 mg, and 30 micro gram epinephrine were injected intravenously. Each injection was performed over 3 s, the most proximal injection port was used, and intravenous fluid was administered at maximal gravitational flow rates. Heart rate was recorded from the electrocardiogram immediately before and for 5 min after injection of each test solution (saline and test doses) at 15-s intervals. Blood pressure cycling was set to every minute, initiated immediately before injection, and continued for 5 min after injection of each test solution. Intravenous fluid administration was standardized such that 750 ml lactated Ringer's solution was administered before injection of study solutions, and an additional 250 ml was infused during the study period. Surgery commenced after the study period, and patients were left undisturbed during the study period.

Statistical Analysis

Demographics were compared with analysis of variance. Baseline heart rate and blood pressure for each test solution were defined as the measurements obtained before injection. Peak measured increases in heart rate and blood pressure were defined as the difference between the baseline values and the greatest measured values after injection of each test solution. Onset of peak measured increases was the time at which these measurements were obtained. Ninety-five-percent confidence intervals applicable to 99% of the general population [12]were calculated for peak increases in heart rate and systolic (SBP), diastolic (DBP), and mean (MBP) blood pressures after injection of saline from all subjects in each anesthetic group. Hemodynamic increases greater than these 95% confidence intervals were defined as positive hemodynamic criteria for detection of intravascular injection of test doses and were determined for each anesthetic group. Dose-effect relationships between epinephrine and peak measured increases in heart rate and SBP, DBP, and MBP were analyzed with linear regression within each anesthetic group. Minimum required doses (MRDs) of epinephrine producing mean peak hemodynamic changes with 95% confidence intervals that exceeded positive hemodynamic criteria were determined from linear regression. Bonferroni correction was used to correct P values for multiple comparisons. A corrected P < 0.05 was considered significant.

Age, height, weight, preinduction hemodynamics, and patient temperature and baseline hemodynamics obtained before injection of test solution did not differ between anesthetic groups (Table 1). Significant dose-effect relationships were identified for epinephrine-induced peak measured increases in heart rate and blood pressures for each anesthetic group (Figure 1, Figure 2, Figure 3, Figure 4). Criteria for positive heart rate and SBP response to intravascular injection of epinephrine-containing test doses and MRDs of epinephrine for production of positive responses were determined (Table 2). Times of onset of peak measured hemodynamic changes were determined (Table 3).

Table 1. Demographics and Hemodynamics before Anesthetic Induction and before Injection of Test Solutions

Table 1. Demographics and Hemodynamics before Anesthetic Induction and before Injection of Test Solutions
Table 1. Demographics and Hemodynamics before Anesthetic Induction and before Injection of Test Solutions

Figure 1. Correlation of dose of epinephrine with peak increases in heart rate (HR) by linear regression. Regression lines display predicted dose-related increases in heart rate (mean with 95% confidence intervals). All correlations are significant. Correlation coefficients range from 0.61 to 0.91.

Figure 1. Correlation of dose of epinephrine with peak increases in heart rate (HR) by linear regression. Regression lines display predicted dose-related increases in heart rate (mean with 95% confidence intervals). All correlations are significant. Correlation coefficients range from 0.61 to 0.91.

Close modal

Figure 2. Correlation of dose of epinephrine with peak measured increases in systolic blood pressure (SBP) by linear regression. Regression lines display predicted dose-related increases in systolic blood pressure (mean with 95% confidence intervals). All correlations are significant. Correlation coefficients range from 0.76 to 0.86.

Figure 2. Correlation of dose of epinephrine with peak measured increases in systolic blood pressure (SBP) by linear regression. Regression lines display predicted dose-related increases in systolic blood pressure (mean with 95% confidence intervals). All correlations are significant. Correlation coefficients range from 0.76 to 0.86.

Close modal

Figure 3. Correlation of dose of epinephrine with peak measured increases in diastolic blood pressure (DBP) by linear regression. Regression lines display predicted dose-related increases in diastolic blood pressure (mean with 95% confidence intervals). All correlations are significant. Correlation coefficients range from 0.74 to 0.86.

Figure 3. Correlation of dose of epinephrine with peak measured increases in diastolic blood pressure (DBP) by linear regression. Regression lines display predicted dose-related increases in diastolic blood pressure (mean with 95% confidence intervals). All correlations are significant. Correlation coefficients range from 0.74 to 0.86.

Close modal

Figure 4. Correlation of dose of epinephrine with peak measured increases in mean blood pressure (MBP) by linear regression. Regression lines display predicted dose-related increases in mean blood pressure (mean with 95% confidence intervals). All correlations are significant. Correlation coefficients range from 0.72 to 0.92.

Figure 4. Correlation of dose of epinephrine with peak measured increases in mean blood pressure (MBP) by linear regression. Regression lines display predicted dose-related increases in mean blood pressure (mean with 95% confidence intervals). All correlations are significant. Correlation coefficients range from 0.72 to 0.92.

Close modal

Table 2. Positive Hemodynamic Criteria for Identification of Intravascular Injection of Test Doses and Minimum Required Dose of Epinephrine Predicted to Produce Mean Increases Exceeding Positive Criteria

Table 2. Positive Hemodynamic Criteria for Identification of Intravascular Injection of Test Doses and Minimum Required Dose of Epinephrine Predicted to Produce Mean Increases Exceeding Positive Criteria
Table 2. Positive Hemodynamic Criteria for Identification of Intravascular Injection of Test Doses and Minimum Required Dose of Epinephrine Predicted to Produce Mean Increases Exceeding Positive Criteria

Table 3. Time until Onset of Peak Measured Hemodynamic Increases after Injection of Epinephrine

Table 3. Time until Onset of Peak Measured Hemodynamic Increases after Injection of Epinephrine
Table 3. Time until Onset of Peak Measured Hemodynamic Increases after Injection of Epinephrine

The first goal of our study was to determine hemodynamic criteria for accurate identification of intravascular injection of an epinephrine-containing test dose during general anesthesia in the absence of epidural anesthesia. Previous hemodynamic criteria have been derived exclusively from awake subjects. [3]Positive criteria were determined for each anesthetic group and calculated to apply to 99% of the general population of healthy, young adults undergoing general anesthesia with isoflurane and nitrous oxide. In such a population, increases in heart rate greater or equal to 8 beats/min, SBP greater or equal to 13 mmHg, DBP greater or equal to 7 mmHg, or MBP greater or equal to 9 mmHg will identify intravascular injection of epinephrine. Other populations, such as the elderly, [13]and other general anesthetics [14]may have different cardiovascular profiles and thus require separate determination of hemodynamic criteria. Our positive criteria derived from healthy adults during general anesthesia with isoflurane suggest that smaller magnitude of hemodynamic changes can be used than are typically used for awake, healthy adults (i.e., increase in heart rate greater or equal to 20 beats/min and SBP greater or equal to 15 mmHg). [3]This is likely due to lesser magnitude of hemodynamic variability observed during general anesthesia with isoflurane. We speculate that decreased hemodynamic variability was due to the direct and indirect cardiovascular depression seen after administration of isoflurane and nitrous oxide. Administration of isoflurane results in dose-dependent reduction in heart rate, [15]systemic vascular resistance, [16]and myocardial contractility. [15]Isoflurane also has indirect cardiovascular effects via dose-dependent attenuation of the sympathetic nervous system. [17–19]Similarly, administration of nitrous oxide also produces dose-dependent cardiac depression [20]and vasodilation. [21]Other possible explanations for decreased hemodynamic variability include immobility, negative chronotropic effects of fentanyl and midazolam, and lack of environmental stimulation. In summary, our findings indicate that increases in heart rate greater or equal to 8 beats/min, SBP greater or equal to 13 mmHg, DBP greater or equal to 7 mmHg, or MBP greater or equal to 9 mmHg will identify intravascular injection of epinephrine in the general population of healthy young adults during general anesthesia with isoflurane and nitrous oxide.

The second goal of our study was to determine hemodynamic responses to epinephrine-containing test doses during general anesthesia in the absence of epidural anesthesia. Our data demonstrate that peak, measured hemodynamic responses vary with depth and type of general anesthesia. During anesthesia with 0.5 MAC isoflurane, MRDs of epinephrine required to produce mean peak hemodynamic changes exceeding positive criteria ranged from 7 to 15 micro gram. Thus, intravascular injection of the standard epidural test dose containing 15 micro gram epinephrine should, on average, produce positive changes in heart rate and blood pressures. However, during anesthesia with 1 MAC isoflurane, 17–19 micro gram epinephrine is the predicted MRD for production of positive mean increases in heart rate, DBP, and MBP.

Thus, the standard 15-micro gram epinephrine test dose probably will not produce sufficiently large increases in these hemodynamics, on average, for detection of intravascular injection. Use of an epinephrine dose greater than 15 micro gram during 1 MAC isoflurane should enhance identification of intravascular injection but may increase the likelihood of cardiac dysrhythmias. [22]Alternatively, the MRD of epinephrine predicted to produce positive increases in SBP during 1 MAC isoflurane is 13 micro gram; thus, increases in SBP may be monitored for identification of intravascular injection.

In contrast, addition of 0.5 MAC nitrous oxide to 0.5 MAC isoflurane also resulted in 1 MAC total anesthesia, yet did not reduce hemodynamic responses to epinephrine (MRDs ranged from 6 to 12 micro gram). Because isoflurane [15]and nitrous oxide [20]directly depress cardiovascular function, different effects of nitrous oxide and isoflurane on the sympathetic nervous system may explain this finding. Isoflurane is a potent inhibitor of the sympathetic nervous system, [17–19,23]whereas nitrous oxide preserves and may enhance sympathetic function. [17,24,25]Thus, the relative preservation of sympathetic function with administration of nitrous oxide may preserve hemodynamic responses to epinephrine.

There are several limitations to our study. First, our data cannot identify a specific epinephrine dose that is 100% sensitive and specific. Rather, MRDs should produce, on average, mean hemodynamic changes that exceed positive criteria. Individual patient responses will vary, and not all patients will experience positive hemodynamic increases after intravascular injection of an MRD. We encourage readers to measure multiple hemodynamic variables to improve sensitivity of the epinephrine test dose for detection of unintentional intravascular injection. Another limitation is the relatively small number of subjects enrolled. However, the significance of our findings should be enhanced by the study design. Each subject was used as their own control, and generalized applicability of findings was improved by the use of 95% confidence intervals and a dose-effect study design. Our use of intermittent and noninvasive measurement of blood pressure may have decreased the sensitivity of our results, yet may have enhanced the clinical value of our findings because of the common use of oscillometric blood pressure monitoring. We note that previous studies examining epidural test doses have used similar methodology. [4,26–28]The standardized administration of fentanyl and midazolam as premedication may have affected patients' responses to epinephrine, but administration of pre-medicants is common clinical practice. Finally, our study was performed without the influence of surgery or epidural anesthesia. Surgical stimulation would be expected to provoke hemodynamic stimulation, and epidural anesthesia may decrease sympathetic tone [29,30]depending on the extent of neural block [31]and type of local anesthetic used. [32]Either situation could alter our results.

In conclusion, MRDs of epinephrine to produce mean positive hemodynamic increases vary with depth and composition of general anesthetic. The standard test dose with 15 micro gram epinephrine should produce, on average, multiple positive hemodynamic responses identifying intravascular injection during anesthesia with 0.5 MAC isoflurane with or without 0.5 MAC nitrous oxide. However, during general anesthesia with 1 MAC isoflurane, 15 micro gram epinephrine is probably insufficient to produce positive increases in heart rate, DBP, or MBP, and either a larger dose of epinephrine should be used or SBP should be monitored.

1.
Shir Y, Raja SN, Frank SM: The effect of epidural versus general anesthesia on postoperative pain and analgesic requirements in patients undergoing radical prostatectomy. ANESTHESIOLOGY 1994; 80:49-56.
2.
Dahl JB, Hansen BL, Hjortso NC, Erichsen CJ, Moiniche S, Kehlet H: Influence of timing on the effect of continuous extradural analgesia with bupivacaine and morphine after major abdominal surgery. Br J Anaesth 1992; 69:4-8.
3.
Guinard JP, Mulroy MF, Carpenter RL, Knopes KD: Test doses: Optimal epinephrine content with and without acute beta-adrenergic blockade. ANESTHESIOLOGY 1990; 73:386-92.
4.
Colonna RP, Lingaraju N, Godfrey SD, Braitman LE: Epidural test dose and intravascular injection in obstetrics: Sensitivity, specificity, and lowest effective dose. Anesth Analg 1992; 75:372-6.
5.
Prince G, McGregor D: Obstetric epidural test doses: A reappraisal. Anaesthesia 1986; 41:1240-50.
6.
Colonna RP, Lingaraju N, Braitman LE: Epidural test dose: Lidocaine 100 mg, not chloroprocaine, is a symptomatic marker of i.v. injection in labouring parturients. Can J Anaesth 1993; 40:714-7.
7.
Moore DC, Batra MS: The component of an effective test dose prior to epidural block. ANESTHESIOLOGY 1981; 55:693-6.
8.
Tanaka M, Yamamoto S, Ashimura H, Iwai M, Matsumiya N: Efficacy of an epidural test dose in adult patients anesthetized with isoflurane: Lidocaine containing 15 ug epinephrine reliably increases arterial blood pressure, but not heart rate. Anesth Analg 1995; 80:310-4.
9.
Eger EI: Isoflurane: A review. ANESTHESIOLOGY 1981; 55:559-76.
10.
Zbinden AM, Maggiorini M, Petersen FS, Lauber R, Thomson DA, Minder CE: Anesthetic depth defined using multiple noxious stimuli during isoflurane/oxygen anesthesia: I. Motor reactions. ANESTHESIOLOGY 1994; 80:253-60.
11.
Hornbein TF, Eger EI, Winter PM, Smith G, Wetstone D, Smith KH: The minimum alveolar concentration of nitrous oxide in man. ANESTHESIOLOGY 1982; 61:553-6.
12.
Glantz SA: Primer of Biostatistics. 2nd edition. New York, Mcgraw-Hill, 1987, pp 186-9.
13.
McKinney MS, Fee JP, Clarke RS: Cardiovascular effects of isoflurane and halothane in young and elderly adult patients. Br J Anaesth 1993; 71:696-701.
14.
Divcic A, Muzi M, Ebert TJ: The effects of clonidine on desflurane-mediated sympathoexcitation in humans. Anesth Analg 1995; 80:773-9.
15.
Palmisano BW, Mehner RW, Stowe DF, Bosnjak ZJ, Kampine JP: Direct myocardial effects of halothane and isoflurane: Comparison between adult and infant rabbits. ANESTHESIOLOGY 1994; 81:718-29.
16.
Priebe H-J: Differential effects of isoflurane on regional right and left ventricular performances, and on coronary, systemic, and pulmonary hemodynamics in the dog. ANESTHESIOLOGY 1987; 66:262-72.
17.
Sellgren J, Ponten J, Wallin BG: Percutaneous recording of muscle nerve sympathetic activity during propofol, nitrous oxide, and isoflurane anesthesia in humans. ANESTHESIOLOGY 1990; 73:20-7.
18.
Kato M, Komatsu T, Kimura T, Sugiyama F, Nakashima K, Shimada Y: Spectral analysis of heart rate variability during isoflurane anesthesia. ANESTHESIOLOGY 1992; 77:669-74.
19.
Deegan R, Bing H, Wood AJJ, Wood M: Effect of enflurane and isoflurane on norepinephrine kinetics: A new approach to assessment of sympathetic function during anesthesia. Anesth Analg 1993; 77:49-54.
20.
Pagel PS, Kampine JP, Schmeling WT, Warltier DC: Effects of nitrous oxide on myocardial contractility as evaluated by the preload recruitable stroke work relationship in chronically instrumented dogs. ANESTHESIOLOGY 1990; 73:1148-57.
21.
Lam AM, Mayberg TS, Eng CC, Cooper JO, Bachenberg KL, Mathisen TL: Nitrous oxide-isoflurane anesthesia causes more cerebral vasodilation than an equipotent dose of isoflurane in humans. Anesth Analg 1994; 78:462-8.
22.
Navarro R, Weiskopf RB, Moore MA, Lockhart S, Eger EI, Koblin D, Lu G, Wilson C: Humans anesthetized with sevoflurane or isoflurane have similar arrhythmic response to epinephrine. ANESTHESIOLOGY 1994; 80:545-9.
23.
Jordan D, Shulman SM, Miller EJ: Esmolol hydrochloride, sodium nitroprusside, and isoflurane differ in their ability to alter peripheral sympathetic responses. Anesth Analg 1993; 77:281-90.
24.
Galletly DC, Westenberg AM, Robinson BJ, Corfiatis T: Effect of halothane, isoflurane and fentanyl on spectral components of heart rate variability. Br J Anaesth 1994; 72:177-80.
25.
Ebert TJ: Differential effects of nitrous oxide on baroreflex control of heart rate and peripheral sympathetic nerve activity in humans. ANESTHESIOLOGY 1990; 72:16-22.
26.
Desparmet J, Mateo J, Ecoffey C, Mazoit X: Efficacy of an epidural test dose in children anesthetized with halothane. ANESTHESIOLOGY 1990; 72:249-51.
27.
Gieraerts R, Van ZA, De WA, Vaes L: Ten ml bupivacaine 0.125% with 12.5 micrograms epinephrine is a reliable epidural test dose to detect inadvertent intravascular injection in obstetric patients: A double-blind study. Acta Anaesthesiol Scand 1992; 36:656-9.
28.
Leighton BL, De SC, Norris MC, Chayen B: Isoproterenol is an effective marker of intravenous injection in laboring women. ANESTHESIOLOGY 1989; 71:206-9.
29.
Fleisher LA, Frank SM, Shir Y, Estafanous M, Kelly S, Raja SN: Cardiac sympathovagal balance and peripheral sympathetic vasoconstriction: Epidural versus general anesthesia. Anesth Analg 1994; 79:165-71.
30.
Valley MA, Bourke DL, Hamill MP, Raja SN: Time course of sympathetic blockade during epidural anesthesia: Laser Doppler flowmetry studies of regional skin perfusion. Anesth Analg 1993; 76:289-94.
31.
Stevens RA, Artuso JD, Kao TC, Bray JG, Spitzer L, Louwsma DL: Changes in human plasma catecholamine concentrations during epidural anesthesia depend on the level of block. ANESTHESIOLOGY 1991; 74:1029-34.
32.
Stevens RA, Beardsley D, White JL, Kao T-Z, Teague PJ, Spitzer L: Does the choice of local anesthetic affect the catecholamine response to stress during epidural anesthesia. ANESTHESIOLOGY 1993; 79:1219-26.