Background

The authors determined the efficacy of using the intubating laryngeal mask airway Fastrach (ILM) as a ventilatory device and aid to flexible lightwand-guided tracheal intubation in patients with unpredicted failed laryngoscope-guided tracheal intubation when managed by experienced anesthetists.

Methods

During a 27-month period, 16 experienced anesthetists agreed to use the ILM as an airway device and airway intubator in patients (aged > 18 yr) with predicted normal airways who were subsequently found to be difficult to intubate (three failed attempts at laryngoscopy). Intubation via the ILM was performed with a flexible lightwand. The number of attempts at ILM placement, the number of adjusting maneuvers, the number of attempts at tracheal intubation via the ILM,and any episodes of hypoxia (oxygen saturation < 90%) were recorded.

Results

Forty-four of 11,621 patients (0.4%) met the inclusion criteria. ILM insertion and ventilation was successful at the first attempt in 40 of 44 patients (91%) and at the second attempt in 4 of 44 (9%). Flexible lightwand-guided tracheal intubation via the ILM was successful in 38 of 44 patients (86%) at the first attempt, 3 of 44 (7%) at the second attempt, 2 of 44 (5%) at the third to fifth attempts, and failed in 1 of 44 (2%). The median number of adjusting maneuvers before successful intubation was 1 (range, 0-4). Hypoxia occurred in 5 patients before ILM insertion (range, 52-82%), but none after ILM insertion. No patient developed hypoxia during or after intubation via the ILM.

Conclusion

The ILM is an effective ventilatory device and aid to flexible lightwand-guided tracheal intubation in adult patients with predicted normal airways in whom laryngoscope-guided tracheal intubation subsequently fails when managed by experienced anesthetists.

THE laryngeal mask airway Classic ™ (LMA ™, Laryngeal Mask Co., Henley-on-Thames, UK) has been incorporated by Benumof into the American Society of Anesthesiologists difficult airway algorithm as a ventilatory device or airway intubator for when intubation fails in the anesthetized patient. 1However, there are only three studies describing its success rate as a ventilatory device 2,3and none describing its success rate as an airway intubator in these situations. The intubating laryngeal mask airway Fastrach ™ (ILM ™, Laryngeal Mask Co.) has greater potential than the LMA™  in the difficult airway because it forms a more effective seal with the glottis, 4insertion is quicker and ventilation easier, 5it is easier to insert in the neutral position, 6and it is a more effective airway intubator. 7Anecdotal reports suggest that the ILM™  has a high success rate as a ventilatory device 8–15(27 cases) or aid to blind 8,9,11–13(13 cases), lightwand-guided 15(1 case), or fiberoptic-guided 10(1 case) intubation after failed laryngoscope-guided intubation, but there have also been a number of failed uses for ventilation 16–18(3 cases) and intubation 11(1 case). In the following prospective study, we determined the efficacy of the ILM™  as a ventilatory device and aid to flexible lightwand–guided tracheal intubation in patients with unpredicted failed laryngoscope-guided tracheal intubation when managed by experienced anesthetists.

The study was performed at the Gennimatas and Sotiria Hospitals in Athens, Greece, between June 1998 and September 2000. Ethics committee approval was obtained for the study, but the ethics committee did not consider written consent necessary. Sixteen anesthetists with at least 2 yr of anesthesia experience participated in the study. All had previous experience with the ILM™  for ventilation and intubation (> five uses), but only six had used it in conjunction with the flexible lightwand. The remaining 10 were shown how to use the flexible lightwand with the ILM™  in at least one patient. All adults (≥ 18 yr) scheduled for surgery with general anesthesia that required tracheal intubation underwent preoperative airway assessment. Patients were excluded from the study if they had any one of the following criteria: (1) Mallampati score 3 or 4; (2) thyromental distance 7 cm or less; (3) head–neck mobility to flexion–extension less than 90 degrees; (4) mouth opening 2.5 cm or less; (5) known difficult airway; and (6) known oropharyngeal or cervical pathology.

Anesthesia management was semistandardized. Monitoring was applied before induction and included an electrocardiograph, pulse oximeter, gas analyzer, noninvasive blood pressure monitor, tidal volume monitor, and airway pressure monitor. The type and dose of induction and nondepolarizing muscle-relaxing agents were at the discretion of the anesthesiologist. The nondepolarizing muscle relaxant was only given after successful face mask ventilation had been demonstrated. Adopting the best head–neck position, applying laryngeal pressure, using a different size–type of laryngoscope blade or gum elastic bougie, as required, optimized conditions for laryngoscope-guided tracheal intubation.

Between intubation attempts, the patient was ventilated via  the face mask. An intubation attempt was defined as insertion of the laryngoscope blade. If intubation failed at the third attempt, the ILM™  was inserted using a single-handed rotational technique, and the cuff was inflated with air until an effective airway was obtained or the maximum cuff volume was reached. A size 4 was used in patients weighing 70 kg or less, and size 5 was used in those weighing more than 70 kg. A maximum of three attempts was allowed. An insertion attempt was defined as rotation of the ILM™  toward the pharynx. Successful placement was defined as a tidal volume of 7 ml/kg without an audible oropharyngeal leak at peak airway pressures of 20 cm H2O or greater.

A well-lubricated, straight silicone endotracheal tube (Euromedical, Malaysia), preloaded with the flexible lightwand, was inserted into the ILM™  tube and advanced beyond the epiglottic elevating bar while observing the glow in the neck. A size 7.0- or 7.5-mm endotracheal tube was used in women, and a size 8.0 mm was used in males. Room lighting was reduced. If a glow could not be seen, the skin over the neck was stretched or the neck flexed or head extended to increase the thyrosternal distance. Whenever slight tactile resistance was felt or the light glow was not correctly located, a predetermined sequence of adjusting maneuvers was instituted (table 1). When the tube easily advanced 8 cm beyond the ILM™ , the anesthesiologist initiated ventilation. If esophageal intubation occurred, the ILM™  was partially withdrawn and the handle extended before a second attempt. If this failed, the ILM™  was partially withdrawn and reinserted before a further attempt. The maximum number of adjusting maneuvers and intubation attempts allowed was four and five, respectively. Between intubation attempts, the patient was ventilated via  the ILM™ .

Table 1. Lightwand-guided Intubation via  the Intubating Laryngeal Mask Airway (ILM ™) Using the Flexible Lighted Catheter: Probable Cause of Resistance and Appropriate Management Strategy Depending of the Location of the Glow on the Neck

Table 1. Lightwand-guided Intubation via  the Intubating Laryngeal Mask Airway (ILM ™) Using the Flexible Lighted Catheter: Probable Cause of Resistance and Appropriate Management Strategy Depending of the Location of the Glow on the Neck
Table 1. Lightwand-guided Intubation via  the Intubating Laryngeal Mask Airway (ILM ™) Using the Flexible Lighted Catheter: Probable Cause of Resistance and Appropriate Management Strategy Depending of the Location of the Glow on the Neck

An intubation attempt through the ILM™  was defined as a forward and backward movement of the endotracheal tube. Cricoid pressure was avoided during use of the ILM™ .

The number of attempts at ILM™  placement, the number adjusting maneuvers, the number of attempts at tracheal intubation through the ILM™ , and any episodes of hypoxia (oxygen saturation < 90%) before or after ILM™  insertion and during or after intubation via  the ILM™  were noted.

There were 44 of 11,621 patients (0.4%) in whom laryngoscope-guided intubation failed after three attempts. The mean age and weight was 52 yr (range, 24–72 yr) and 71 kg (range, 46–94 kg), respectively. The male:female ratio was 24:20. Failed intubation was associated with an inability to view the vocal cords in all patients. Difficulty with face mask ventilation occurred in 5 of 44 (11%) of these patients. ILM™  insertion and ventilation was successful at the first attempt in 40 of 44 patients (91%) and at the second attempt in 4 of 44 patients (9%). There were no failures. Lightwand-guided tracheal intubation via  the ILM™  was successful in 38 of 44 patients (86%) at the first attempt, 3 of 44 (7%) at the second attempt, 2 of 44 (5%) at the third to fifth attempts, and failed in 1 of 44 (2%) (table 2). In the latter patient, persistent esophageal intubation occurred, and the ILM™  was used to facilitate oxygenation until the patient was awake. The median number of adjusting maneuvers before successful intubation was 1 (range, 0–4;table 2). Hypoxia occurred in five patients before ILM™  insertion (range, 52–82%), but none after ILM™  insertion. All patients were still paralyzed when the ILM™  was used. No patient developed hypoxia during or after intubation via  the ILM™ . There were no adverse outcomes.

Table 2. Distribution of the Number of Airway Manipulations and Intubation Attempts with the Intubating Laryngeal Mask Airway

Table 2. Distribution of the Number of Airway Manipulations and Intubation Attempts with the Intubating Laryngeal Mask Airway
Table 2. Distribution of the Number of Airway Manipulations and Intubation Attempts with the Intubating Laryngeal Mask Airway

We found that the ILM™  was a successful ventilatory device in 44 of 44 patients (100%) and was a successful aid to lightwand-guided intubation in 43 of 44 patients (98%). This success rate is similar to that reported by Fukutome et al. , 11who reported successful ventilation in 8 of 8 patients (100%) and successful blind intubation in 7 of 8 patients (87%) with the ILM™  in anesthetized adults after failed laryngoscope-guided intubation. Our success rate for ventilation is similar to that of Parmet et al. , 3who reported successful ventilation with the LMA™  in 16 of 17 adults (94%) after failed laryngoscope-guided intubation and failed face mask ventilation. Our success rate was similar to an earlier report by our group using flexible lightwand–guided intubation via  the ILM™  in patients with predicted normal airways in whom laryngoscope-guided intubation was not attempted. 19Interestingly, we found that the ILM™  was a successful ventilatory device in 5 of 5 patients who were also difficult to ventilate via  face mask. These numbers are too small to determine the efficacy of the ILM™  after failed face mask ventilation, but the ILM™  is a more effective ventilatory device than the face mask in patients with normal airways. 5 

We used lightwand-guided intubation via  the ILM™  because it has a higher success rate than blind intubation in patients with predicted normal airways, 20and fiberoptic equipment was not widely available at our institute. Our success rate for the flexible lightwand compares favorably with other ILM™  intubation techniques in abnormal airways, including the following: blind intubation, 93% (28 of 30), 11100% (13 of 13), 8and 77% (17 of 22) 21; and nonflexible lightwand–guided intubation, 100% (6 of 6). 22Surprisingly, there have been no case series reporting use of the fiberoptic scope in these situations.

There are insufficient data to make firm recommendations about which intubation technique with the ILM™  is best, but blind techniques are probably undesirable because of the high incidence of esophageal intubation (26%). 23We used the ILM™  without cricoid pressure because it impedes insertion and intubation via  the ILM™  in patients with normal airways. 24 

Our study has a number of limitations. First, all participants had at least 1 yr of anesthesia training and some experience of intubation via  the ILM™ . Our findings may therefore not apply to the novice or those inexperienced with the ILM™ . Interestingly, nonanesthetists have a higher success rate with the ILM™  than the face mask in patients with normal airways and blind intubation success rates that are similar to direct laryngoscopy. 25In addition, Kihara et al.  26found that there was no learning curve with the ILM™  lightwand technique during 150 uses by a single anesthetist. Second, we studied patients with unpredicted difficult airways, and our success rates may not apply to the predicted difficult airway. However, during the study period we used the same technique on 48 patients who had predicted difficult airways (Mallampati score 3 or 4; thyromental distance ≤ 7 cm; head–neck mobility to flexion–extension < 90 degrees; mouth opening > 2.5 cm) and found that ILM™  insertion and ventilation were successful at the first attempt in 43 of 48 patients (90%) and at the second attempt in 5 of 48 (10%); intubation was successful in 48 of 48 (100%) and 43 of 48 (90%) at the first attempt. Third, all of our patients were paralyzed when the ILM™  was used, and our data may not apply to the nonparalyzed patient. However, there is evidence that the ILM™  can be inserted and used for intubation without muscle relaxation provided anesthesia depth is sufficient. 27–29 

In conclusion, the ILM™  is an effective ventilatory device and aid to flexible lightwand–guided tracheal intubation in adult patients with predicted normal airways in whom laryngoscope-guided tracheal intubation subsequently fails when managed by experienced anesthetists.

1.
Benumof J: The laryngeal mask airway and the ASA difficult airway algorithm. A nesthesiology 1996; 84: 686–99
2.
Gataure PS, Hughes JA: The laryngeal mask airway in obstetrical anaesthesia. Can J Anaesth 1995; 42: 130–3
3.
Parmet JL, Colonna-Romano P, Horrow JC, Miller F, Gonzales J, Rosenberg H: The laryngeal mask airway reliably provides rescue ventilation in cases of unanticipated difficult tracheal intubation along with difficult mask ventilation. Anesth Analg 1998; 87: 661–5
4.
Keller C, Brimacombe J: Pharyngeal mucosal pressures, airway sealing pressures and fiberoptic position with the intubating versus the standard laryngeal mask airway. A nesthesiology 1999; 90: 1001–6
5.
Choyce A, Avidan MS, Patel C, Harvey A, Timberlake C, McNeilis N, Glucksman E: Comparison of laryngeal mask and intubating laryngeal mask insertion by the naive intubator. Br J Anaesth 2000; 84: 103–5
6.
Asai T, Wagle AU, Stacey M: Placement of the intubating laryngeal mask is easier than the laryngeal mask during manual in-line stabilisation. Br J Anaesth 1999; 82: 712–4
7.
Lucas DN, Yentis SM: A comparison of the intubating laryngeal mask tracheal tube with a standard tracheal tube for fibreoptic intubation. Anaesthesia 2000; 55: 358–61
8.
Brain AIJ, Verghese C, Addy EV, Kapila A, Brimacombe J: The intubating laryngeal mask. II: A preliminary clinical report of a new means of intubating the trachea. Br J Anaesth 1997; 79: 704–9
9.
Parr MJA, Gregory M, Baskett PJF: The intubating laryngeal mask. Use in failed and difficult intubation. Anaesthesia 1998; 53: 343–8
10.
Joo H, Rose K: Fastrack—A new intubating laryngeal mask airway: Successful use in patients with difficult airways. Can J Anaesth 1998; 45: 253–6
11.
Fukutome T, Amaha K, Nakazawa K, Kawamura T, Noguchi H: Tracheal intubation through the intubating laryngeal mask airway (LMA-Fastrach) in patients with difficult airways. Anaesth Intens Care 1998; 26: 387–91
12.
Rosenblatt WH, Murphy M: The intubating laryngeal mask: Use of a new ventilating-intubating device in the emergency department. Ann Emerg Med 1999; 33: 234–8
13.
Watson NC, Hokanson M, Maltby JR, Todesco JM: The intubating laryngeal mask airway in failed fibreoptic intubation. Can J Anaesth 1999; 46: 376–8
14.
Cros AM, Maigrot F, Esteben D:[Fastrach laryngeal mask and difficult intubation]. Ann Fr Anesth Reanim 1999; 18: 1041–6
15.
Kihara S, Watanabe S, Taguchi N, Brimacombe J: Airway rescue with the intubating laryngeal mask in a patient with an unexpectedly large epiglottic cyst. Anaesthesiologie Intensivmedizin Notfalmedizin Schmerztherapie 2000; 35: 774–5
16.
Seto A, Aoyama K, Takenaka I, Kadoya T: Ventilation difficulties through the intubating laryngeal mask. Anesth Analg 1999; 88: 1181–2
17.
Asai T, Hirose T, Shingu K: Failed tracheal intubation using a laryngoscope and intubating laryngeal mask. Can J Anaesth 2000; 47: 325–8
18.
Preis C, Czerny C, Preis I, Zimpfer M: Variations in ILMA external diameters: Another cause of device failure. Can J Anaesth 2000; 47: 886–9
19.
Dimitriou V, Voyagis GS: Light-guided intubation via the intubating laryngeal mask using a prototype illuminated catheter: Clinical experience in 400 patients. Acta Anaesthesiol Scand 2000; 44: 1002–6
20.
Kihara S, Watanabe S, Taguchi N, Suga A, Brimacombe J: A comparison of blind and lightwand-guided tracheal intubation through the intubating laryngeal mask. Anaesthesia 2000; 55: 427–31
21.
Smith BL: Anaesthesia for patients with juvenile chronic arthritis (Still's disease) (letter). Anaesthesia 1998; 53: 314
22.
Agro F, Brimacombe J, Carassiti M, Marchionni L, Morelli A, Cataldo R: The intubating laryngeal mask: Clinical appraisal of ventilation and blind tracheal intubation in 110 patients. Anaesthesia 1998; 53: 1084–90
23.
Kihara S, Watanabe S, Taguchi N, Suga A, Brimacombe J: Tracheal intubation with the Macintosh laryngoscope vs intubating laryngeal mask airway in adults with normal airways. Anaesth Intens Care 2000; 28: 281–6
24.
Harry RM, Nolan JP: The use of cricoid pressure with the intubating laryngeal mask. Anaesthesia 1999; 54: 656–9
25.
Avidan MS, Harvey A, Chitkara N, Ponte J: The intubating laryngeal mask airway compared with direct laryngoscopy. Br J Anaesth 1999; 83: 615–7
26.
Kihara S, Watanabe S, Taguchi N, Yaguchi Y, Yamasaki Y, Brimacombe J: No learning curve seen in the light guided intubation though the intubating laryngeal mask airway (abstract). Anesth Analg 2000; 90: S215
27.
Cereda M, De Marchi L, Villa F, Nacoti M, Maisano P: Tracheal intubation without paralysis with intubating laryngeal mask (abstract). A nesthesiology 2000; 93: A1366
28.
Rocchiccioli C, Blumen M, Chabolle F, Fischler M: Successful use of LMA Fastrach® (FT) in patients with obstructive sleep apnea syndrome and predictive signs of difficult airway (abstract). A nesthesiology 2000; 93: A1112
29.
Van Vlymen JM, Coloma M, Tongier WK, White PF: Use of the intubating laryngeal mask airway: Are muscle relaxants necessary? A nesthesiology 2000; 93: 340–5